Anemometers and Windvanes in action!
Windspeed Ltd (Vector Instruments), 115 Marsh Road, RHYL, N. Wales, LL18 2AB, United Kingdom.
Windspeed Limited (trading as Vector Instruments)
115 Marsh Road, RHYL, LL18 2AB, United Kingdom.
Tel: 01745 350700 - Fax: 01745 344206
Manufacturers of high quality anemometers and windvanes since 1972
Click for info on: Wind Speed sensors Click for info on: Wind Direction Sensors Click for info on: Masts + Mountings Click for info on: Air Temperature sensors Click for info on: Masts + Mountings
 Friday, September 03 2010   Search site:  

Latest Weather...
(Rhyl, N.Wales, UK)
Wind Speed:  4.0 mph
Wind Direction:  142 °
Air Temp.:  14.7 °C
Rel. Humidity:  73.2 %
(updated at: 00:06 UK time)

  • Home
  • Contact Us
  • Products
  • Applications
  • Calibration
  • Repairs/Spares
  • Agents/Distributors
  • Support
  • Useful Information
  • Help...
  • Downloads
  • Site Search
  • RoHS
  • Wind Assessment
  • Links, Reports and Papers
  • About Vector Instruments

    Registered User Login ...
    Username

    Password
    Lost Password?
    New User? Register here...

  • Click Übersetzen Sie zu deutschem verwendendem Google Traduisez à Google employant français
    Traduzca a Google que usa español Traduca a Google usando italiano Traduza a Google usando-se portuguese
    to translate
    this page using:
    Google
    Notes:
    This website requires Javascript and Cookies to be enabled for correct operation.
    Use subject to Terms & Conditions.
    Anemometers

    (anemometer)  Our A100 Series Anemometers are robustly constructed using weather resisting plastics, anodised aluminium and stainless steels enabling them to withstand continuous exposure to the weather, including marine environments, making them suitable for a wide range of applications where accuracy and sensitivity are important.

    The A100 series anemometers all share the same basic construction and use the same R30 series 3-cup Rotors. Different internal modules and components are used to provide various output signals. The use of a precision ball-race mounted shaft ensures the essential low threshold speed and good repeatability. The outline and mechanical design, common to all the A100 series, remains largely unchanged since the introduction of the original Porton™ Anemometer in 1972, the electronics modules being continuously developed during this time to provide a well tried, durable and reliable product.

    Anemometers have, until recent years, only been calibrated/evaluated in wind tunnels. Investigation by the wind power industry has found that various anemometer designs behave differently in field conditions where there is considerable turbulence. The Vector Instruments A100 design is one of a very few which has been subjected to field trials, and these have shown that Vector Instruments' A100L2, A100LK, A100K and A100LM anemometers (using the R30/K2, R30/K and R30/M3 rotors) are amongst the very few cup anemometer designs which can be classified as having "First Class" performance according to the requirements of the IEC61400-12-1 when suitably sited and operated. This high performance classification means that measurements are accurate in the actual wind conditions experienced in the field (as opposed to just being accurate in the artificial conditions of a low-turbulence wind tunnel) making them the clear choice for wind assessment applications.

    In operation, the wind causes the rotor to rotate at a speed proportional to the wind speed. This rotation is sensed in our optoelectronic anemometers using a slotted disk and an optical beam. In the case of the switching anemometer the rotation is sensed using a balanced system of magnets and a reed-switch.

    Options common to all the anemometers include anti-icing heaters, marine versions/rotors and mounting adaptors and anti-surge protection.

    See also:
  • Anemometers for Wind Turbine Testing and Wind Farm Site Assessment.
  • additional information regarding obtaining the highest accuracy measurements with our instruments.
  • MEASNET calibrations and IEC classification/standards.

  • What is the difference between "M" and "K" type instruments (e.g. A100LM and A100LK) ?

  • Do I have to use a "K" instrument to measure the wind speed in knots and a "M" instrument to measure in m/s ?

  • What is the A100R/K variant and why/when should it be used?
  • What is the "K" in A100R/K for?
  • Anemometer Selection Table:

    Type

    Pulse/Frequency Output

    Resolution

    Power Supply Required

    Additional Features

    Typical Applications

    A100L2

    0..1500Hz = 0..150Knots
    (10Hz per Knot) nominal)

    0.05m

    6.5 to 28V DC powered
    (@1.5mA typical)

    First Class, Low power,
    Analog/Voltage Output:
    0..2.5v = 0..150Knots nominal

    Datalogger/AWS/WindAssessment

    A100LK

    0..1500Hz = 0..150Knots
    (10Hz per Knot nominal)

    0.05m

    4.75 to 28V DC powered
    (@1mA typical)

    First Class, Low power

    Datalogger/AWS/WindAssessment

    A100LM

    0..750Hz = 0..75m/s
    (10Hz per m/s nominal)

    0.1m

    4.75 to 28V DC powered
    (@1mA typical)

    First Class, Low power

    Datalogger/AWS/WindAssessment

    A100R/K

    1 pulse per revolution
    (1.287m wind-run = 0.777Hz per m/s nominal)

    1.25m

    No power required

    First Class, bounce-free mercury-wetted reed switch,
    optimal cosine response

    Datalogger/AWS/WindAssessment

     

    A100M

    0..750Hz = 0..75m/s
    (10Hz per m/s nominal)

    0.1m

    10 to 30V DC powered
    (@35mA max)

    Anti-Surge

    Industrial/control/PLC

    A100K

    0..1500Hz = 0..150Knots
    (10Hz per Knot nominal)

    0.05m

    10 to 30V DC powered
    (@35mA max)

    Anti-Surge

    Industrial/control/PLC

    A100S

    1 pulse per revolution
    (1.25m wind-run = 0.8Hz per m/s nominal)

    1.25m

    10 to 30V DC powered
    (@35mA max)

    Anti-Surge

    Industrial/control/PLC

    A100R

    1 pulse per revolution
    (1.25m wind-run = 0.8Hz per m/s nominal)

    1.25m

    No power required

    bounce-free mercury-wetted reed switch

    Datalogger/AWS/PLC



    A100 Series Anemometers - First Choice for First Class

    Vector Instruments' A100 Series Anemometers are among the very few available having Class 1 performance ("First Class") according to the requirements of IEC and MEASNET standards.

    Available anemometer types include:
    • Low-Power Optoelectronic, Analog/Voltage AND Pulse/Frequency Output
      - A100L2 Anemometer
      (ideal for most data-loggers)

    • Low-Power Optoelectronic, Pulse/Frequency Output
      - A100LM and A100LK Anemometers
      (also ideal for most data-loggers)

    • Zero-Power, Contact-Closure (Reed Switch)
      - A100R Anemometer
      (lowest power of all, suitable for most dataloggers)

    • Optoelectronic, Pulse/Frequency Output
      - A100M and A100K and A100S Anemometers
      (suited for connection to PLCs)

    • Analogue/Voltage Output
      - Porton A100 and A100H Anemometers
    A100 Series Anemometer Dimensions (mm) 


    Unlike some other manufacturers, we do not manufacture a "combined" wind speed and wind direction sensor. With our product range you have the flexibility to chose an anemometer and windvane with appropriate output signals and mount them together at the top of a mast using one our 405-1 series mounting arms.

    We do not manufacture "generator" type anemometers either, nor do we manufacture equipment for generating power from the wind (although our anemometers are commonly used for surveying and evaluating the suitability of a site for wind power generation).
    Windspeed Ltd (Vector Instruments)
    Windspeed Limited (trading as Vector Instruments),
    115 Marsh Road, RHYL, North Wales, LL18 2AB, United Kingdom
    Tel: +44 (0) 1745 350700   Fax: +44 (0) 1745 344206
    Email: sales@windspeed.co.uk
     
    Website design and content is copyright (c) 2003-2010 Windspeed Limited (unless otherise stated). All trademarks are acknowledged.
    Page Rendered in: 0.343890 seconds. - Powered by Mambo.